Precision Optical Spectrum Analyzer with SMA905 Interface – 530-1100nm Wavelength Range

19 People watching this product now!

Apple Shopping Event

Hurry and get discounts on all Apple devices up to 20%

Sale_coupon_15

$160.00

  • Warranty 1 year
  • Free 30-Day returns

Payment Methods:

Description

The Precision Optical Spectrum Analyzer (OSA) is a sophisticated measurement instrument designed for comprehensive spectral analysis of optical signals across the 530-1100nm wavelength range. Featuring a high-resolution detection system and SMA905 optical interface, this analyzer provides accurate spectral characterization for laser systems, optical communications, research laboratories, and quality control applications. The instrument delivers detailed spectral data with excellent wavelength accuracy and optical power measurement capabilities, making it an essential tool for photonics professionals and researchers.

Key Features

  • Broad Wavelength Coverage: 530-1100nm spectral range with high resolution

  • Precision SMA905 Interface: Standard optical connector for reliable fiber coupling

  • High-Resolution Detection: Detailed spectral analysis with fine wavelength resolution

  • Comprehensive Data Output: Complete spectral data sets for analysis and documentation

  • Robust Mechanical Design: Durable construction with precise mounting capabilities

  • Multi-Format Data Export: Compatible with various analysis software platforms

  • Calibrated Performance: Factory calibrated for accurate wavelength and power measurements

  • User-Friendly Operation: Intuitive interface for efficient measurement workflows

Technical Specifications

Optical Performance:

  • Wavelength Range: 530 nm to 1100 nm

  • Wavelength Accuracy: ±0.5 nm (typical)

  • Wavelength Resolution: 0.1 nm (selectable resolution settings)

  • Optical Resolution Bandwidth: 0.2 nm to 5 nm (adjustable)

  • Dynamic Range: 60 dB (typical)

  • Sensitivity: -70 dBm (typical)

  • Polarization Dependence: < 0.5 dB

  • Insertion Loss: < 3.0 dB (including connector losses)

  • Return Loss: > 40 dB

  • Linearity: ±0.5 dB over full dynamic range

  • Measurement Speed: < 2 seconds for full spectrum scan

  • Sampling Resolution: 0.01 nm data point spacing

Mechanical Specifications:

  • Optical Interface: SMA905 connector with precision alignment

  • Mounting Thread: M22 × 0.75 mm external thread for secure attachment

  • Fixed Screw Holes: Multiple M3 screw holes for stable mounting

  • Laser Ranging Mount: Dedicated mounting points for laser distance measurement accessories

  • Dimensions: 128 mm × 182 mm (standard footprint, height varies by model)

  • Weight: Approximately 1.2 kg (varies by configuration)

  • Enclosure Material: Anodized aluminum for durability and thermal stability

  • Finish: Black anodized with laser-etched markings

Electrical & Control Specifications:

  • Power Requirements: 12V DC, 2A (power supply included)

  • Control Interface: USB 2.0/3.0 for computer connection

  • Data Interface: Ethernet optional (select models)

  • Operating Temperature: 10°C to 40°C

  • Storage Temperature: -10°C to 60°C

  • Humidity Range: 20% to 80% non-condensing

  • Software Compatibility: Windows 10/11, Linux, macOS

  • API Access: Programmable interface for automated measurements

Performance Data (from Optical Analysis Report):

The analyzer provides comprehensive spectral data across the measurement range. Sample performance characteristics include:

  • Consistent Power Response: Maintains measurement accuracy across entire spectrum

  • Stable Wavelength Registration: Precise wavelength mapping with minimal drift

  • Repeatable Measurements: High measurement repeatability for reliable comparisons

  • Spectral Purity: Excellent signal-to-noise ratio for accurate peak detection

SKU Details

Standard Models by Size Configuration:

  • SKU-OSA-B6: 128mm × 182mm × 48mm (H) configuration

  • SKU-OSA-B7: 128mm × 182mm × 46mm (H) configuration

  • SKU-OSA-B8: 128mm × 182mm × 44mm (H) configuration

  • SKU-OSA-B9: 128mm × 182mm × 42mm (H) configuration

  • SKU-OSA-B10: 128mm × 182mm × 40mm (H) configuration

  • SKU-OSA-B11: 128mm × 182mm × 38mm (H) configuration

  • SKU-OSA-B12: 128mm × 182mm × 36mm (H) configuration

  • SKU-OSA-B13: 128mm × 182mm × 34mm (H) configuration

  • SKU-OSA-B14: 128mm × 182mm × 32mm (H) configuration

  • SKU-OSA-B15: 128mm × 182mm × 30mm (H) configuration

Specialized Configurations:

  • SKU-OSA-HIGH-RES: Enhanced resolution model (0.05 nm resolution)

  • SKU-OSA-EXTENDED: Extended wavelength range (400-1100 nm)

  • SKU-OSA-INDUSTRIAL: Industrial-grade with enhanced durability

  • SKU-OSA-RESEARCH: Research-grade with maximum precision

Accessory Packages:

  • SKU-ACC-CALIBRATION: NIST-traceable calibration package

  • SKU-ACC-SOFTWARE: Advanced analysis software suite

  • SKU-ACC-MOUNTING: Complete mounting kit with brackets

  • SKU-ACC-FIBERS: Set of calibration fibers and connectors

  • SKU-ACC-CARRY-CASE: Professional transport and storage case

  • SKU-ACC-TRAINING: Online training and certification

Applications

  • Laser Characterization: Spectral analysis of laser diodes, fiber lasers, and solid-state lasers

  • Optical Communication: DWDM, CWDM system testing and monitoring

  • Research & Development: Photonics research, material spectroscopy

  • Quality Control: Manufacturing testing of optical components

  • Medical Optics: Analysis of medical laser systems

  • Environmental Monitoring: Spectral analysis for sensing applications

  • Educational Laboratories: University and technical training

  • Industrial Process Control: Real-time spectral monitoring

Measurement Capabilities

  • Spectral Power Distribution: Complete spectral power measurement

  • Center Wavelength Determination: Accurate peak wavelength identification

  • Bandwidth Measurement: 3dB, 10dB, and 20dB bandwidth calculation

  • Side Mode Suppression Ratio (SMSR): For laser source characterization

  • Optical Signal-to-Noise Ratio (OSNR): Signal quality assessment

  • Spectral Linewidth Analysis: For narrow linewidth sources

  • Wavelength Drift Monitoring: Long-term stability assessment

  • Multiple Peak Analysis: Simultaneous measurement of multiple spectral features

Calibration & Accuracy

  • Factory Calibration: Each unit calibrated using reference standards

  • Calibration Traceability: NIST-traceable wavelength and power calibration

  • Regular Recalibration: Recommended annual recalibration service

  • Calibration Points: Multiple points across operational range

  • Uncertainty Documentation: Complete measurement uncertainty analysis provided

  • Calibration Certificate: Detailed certificate included with each instrument

Installation & Operation

  • Mounting: Standard optical bench mounting with multiple screw points

  • Alignment: Precision alignment features for optimal optical coupling

  • Connection: SMA905 interface ensures reliable fiber connection

  • Software Setup: Quick installation with comprehensive software package

  • Warm-up Time: < 15 minutes to stabilized operation

  • Maintenance: Minimal maintenance required, periodic cleaning recommended

Package Includes

  • 1 × Optical Spectrum Analyzer Unit (specified model)

  • 1 × SMA905 Optical Interface Connector

  • 1 × 12V DC Power Supply

  • 1 × USB Data Cable

  • 1 × Installation and Mounting Hardware Set

  • 1 × Comprehensive User Manual

  • 1 × Quick Start Guide

  • 1 × Calibration Certificate

  • 1 × Software Installation Package

  • 1 × Protective Dust Cover

Software Features

  • Real-time Display: Live spectral display with continuous updating

  • Data Analysis: Advanced peak detection, integration, and comparison tools

  • Export Formats: CSV, Excel, MATLAB, and image formats supported

  • Automation: Scripting capability for automated measurement sequences

  • Remote Control: Network control option for distributed systems

  • Database Integration: Measurement database with search and retrieval

  • Report Generation: Automatic report generation with customizable templates

Safety & Compliance

  • Laser Safety: Designed for safe operation with optical sources

  • Electrical Safety: CE, RoHS compliant

  • EMC Compliance: Meets electromagnetic compatibility standards

  • Environmental: Compliant with environmental regulations

  • Quality Standards: Manufactured under ISO 9001 quality system


For detailed application notes, custom calibration requirements, or technical consultation regarding specific measurement scenarios, please contact our optical measurement engineering team. We provide comprehensive support for spectral analysis applications across research, industrial, and telecommunications environments.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Precision Optical Spectrum Analyzer with SMA905 Interface – 530-1100nm Wavelength Range”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.