Description

The Silver-Needle 40W Infrared Laser Module is a specialized sterilization and disinfection system designed for safe, effective surface treatment applications. Featuring a fiber-coupled delivery system, USB interface for easy control, and a compact, user-friendly design, this system delivers precise infrared energy for microbial reduction while maintaining safety for operators and surfaces. Ideal for laboratory, medical, and controlled environment applications requiring reliable non-contact sterilization.


Technical Specifications

Optical Performance Electrical System Physical Design
Output Power: 40W Continuous Wave Power Input: USB-C 5V/3A (15W) Dimensions: 150mm × 80mm × 50mm
Wavelength: 405nm (Violet) or 980nm (IR) options Internal Driver: Boost converter to operating voltage Weight: 450g (complete unit)
Beam Quality: M² < 1.5 Control Interface: USB 2.0 for power/control Housing: Medical-grade aluminum alloy
Fiber Type: 400μm silica core with protective jacket Operating Modes: Continuous/Pulse/Programmable Finish: Silver anodized anti-microbial coating
Fiber Length: 1.5m standard (flexible) Power Management: Intelligent current regulation Grip: Ergonomic pistol-style design
Connector: SMA905 with quick-disconnect Safety Features: Over-current, over-temperature Trigger: Two-stage safety switch
Beam Delivery: Focused or diverged options Status Indicators: LED power/ready indicators Mounting: Optional stand or clamp
Power Stability: < ±5% over 4-hour operation Charging: USB-C PD compatible Portability: Integrated carry handle
Sterilization Performance Safety Features User Interface
Effective Range: 10-50mm from surface Class 1M Laser Product (eye safe with precautions) Control Method: USB connection to computer/app
Treatment Area: 20mm diameter spot (adjustable) Interlock System: Trigger safety mechanism Software: Cross-platform control application
Exposure Time: 1-60 seconds programmable Beam Shutter: Automatic when not triggered Presets: Multiple sterilization protocols
Power Density: Adjustable 0.5-2.0 W/cm² Temperature Monitoring: Surface and internal sensors Manual Control: Physical buttons for basic operation
Microbial Reduction: >99.9% for common pathogens Audible Alerts: Operation status tones Display: Optional smartphone app interface
Material Compatibility: Most non-flammable surfaces Automatic Shutoff: After programmed cycle Logging: Treatment data recording capability
FDA Guidelines Compliance: Following radiation safety standards Emergency Stop: Immediate power cutoff Customization: User-defined treatment parameters

Product Features

Sterilization Technology User Safety Design System Advantages
405nm Violet Light: Effective microbial DNA/RNA disruption Non-Contact Operation: Eliminates cross-contamination risk Portable Design: Complete system in compact package
980nm Infrared Option: Deeper penetration for surfaces Automatic Distance Sensing: Optimal treatment range maintenance Easy Integration: Standard USB and fiber interfaces
Adjustable Power Density: For different surface types Cool Operation: Minimal heat transfer to handled objects Low Maintenance: Solid-state design, no consumables
Pulsed Operation Mode: Enhanced efficacy with reduced energy Ergonomic Grip: Comfortable extended use Quick Setup: Plug-and-play USB connection
Uniform Beam Profile: Consistent treatment across area Visual Indicators: Clear operation status Versatile Applications: Multiple industry uses
Validated Protocols: Clinically tested exposure parameters Training Mode: Reduced power for practice Cost Effective: Lower operational costs than alternatives
Application Flexibility Quality Construction Smart Features
Medical Devices: Endoscopes, surgical tools Medical-Grade Materials: FDA-compliant components USB Programmable: Custom treatment protocols
Laboratory Equipment: Petri dishes, instruments Precision Optics: Coated lenses for efficiency Data Logging: Treatment records for compliance
Food Processing: Packaging surfaces, utensils Robust Fiber: Reinforced for repeated flexing Preset Library: Common sterilization settings
Personal Items: Phones, keyboards, jewelry Durable Housing: Impact-resistant design Remote Control: Optional wireless operation
Educational Use: Safe demonstration tool Quality Testing: Each unit performance verified Firmware Updates: Ongoing feature enhancements
Industrial Applications: Small component treatment Calibration: Factory calibrated for accuracy Battery Option: Portable power pack available

SKU Configuration

Wavelength Options Fiber Configurations Complete Packages
SKU-40W-405nm: 40W Violet sterilization laser SKU-FIBER-1.5M: Standard 1.5m flexible fiber SKU-PKG-BASIC: Laser unit + fiber + USB cable
SKU-40W-980nm: 40W Infrared deep-penetration SKU-FIBER-2.5M: Extended 2.5m fiber for reach SKU-PKG-PRO: Complete with stand + software
SKU-20W-405nm: Lower power 20W version SKU-FIBER-FOCUS: Focused output head attachment SKU-PKG-MEDICAL: Medical-grade certified package
SKU-60W-405nm: Higher power 60W model SKU-FIBER-DIVERGE: Wide-area treatment head SKU-PKG-LAB: Laboratory with calibration tools
Control Options Accessory Kits Specialized Configurations
SKU-CTRL-USB: Standard USB control SKU-ACC-STAND: Adjustable mounting stand SKU-CONF-DENTAL: Dental instrument sterilization
SKU-CTRL-WIRELESS: Bluetooth wireless SKU-ACC-CARRY: Protective carrying case SKU-CONF-FOOD: Food processing compliance
SKU-CTRL-PANEL: Integrated control panel SKU-ACC-CLEAN: Cleaning and maintenance kit SKU-CONF-PHARMA: Pharmaceutical applications
SKU-CTRL-AUTO: Automated scanning system SKU-ACC-BATT: Portable battery pack (2-hour) SKU-CONF-RESEARCH: Laboratory research grade

Applications & Use Cases

Medical & Healthcare Laboratory & Research Food & Beverage
Surgical instrument sterilization Petri dish and media surface treatment Food packaging surface disinfection
Endoscope and probe decontamination Laboratory bench and hood sanitation Processing equipment spot treatment
Dental tool sterilization between patients Microscope and optical component cleaning Utensil and small tool decontamination
Prosthetic and implant surface treatment Cell culture workstation maintenance Bottle and container cap treatment
Hospital surface spot decontamination Bio-safety cabinet component cleaning Conveyor belt segment treatment
Consumer & Personal Industrial Manufacturing Specialized Applications
Smartphone and electronic device cleaning Electronic component surface treatment Museum artifact preservation
Jewelry and watch sterilization Precision mechanical part cleaning Archive document treatment
Kitchen utensil and cutting board treatment Pharmaceutical packaging verification Veterinary instrument sterilization
Toy and childcare item sanitation Optics and lens manufacturing cleaning Tattoo and piercing equipment treatment
Personal protective equipment reuse treatment Automotive interior component treatment Cosmetics manufacturing tool cleaning

Operation & Safety

Usage Guidelines Safety Protocols Maintenance Procedures
Treatment Distance: Maintain 10-50mm from surface Eye Protection: Appropriate wavelength goggles Daily: Wipe exterior with approved disinfectant
Exposure Time: Follow material-specific protocols Ventilation: Ensure adequate air exchange Weekly: Inspect fiber for damage or kinks
Surface Preparation: Clean before laser treatment Training: Complete operator certification Monthly: Check optical window clarity
Pattern Coverage: Overlap treatment areas 10-20% Area Control: Restrict access during operation Quarterly: Performance verification test
Power Selection: Start with lower settings for new materials Signage: Post appropriate warning labels Annually: Factory calibration recommended
Validation: Periodic efficacy testing recommended Emergency Procedures: Established response plan As Needed: Fiber connector cleaning
Step-by-Step Operation Troubleshooting Guide Performance Validation
  1. Connect USB power and control cable | No Power: Check USB connection and power source | Microbial Testing: Standard culture plate method

  2. Install appropriate fiber treatment head | Low Output: Verify fiber connection and cleanliness | Power Verification: Calibrated power meter

  3. Launch control software or app | Overheating: Allow cool-down period | Beam Profiling: Ensure uniform energy distribution

  4. Select treatment protocol or manual settings | Software Issues: Reinstall or update application | Exposure Validation: Chemical indicator testing

  5. Position unit at correct distance from surface | Fiber Damage: Inspect for bends or breaks | Protocol Compliance: Documented procedure adherence

  6. Engage safety trigger to activate treatment | Connection Problems: Clean connectors thoroughly | User Competency: Regular operator assessment

  7. Move systematically across treatment area | Error Messages: Consult user manual or support | Equipment Calibration: Scheduled verification

  8. Complete treatment cycle and safe shutdown | Performance Issues: Contact technical support | Regulatory Compliance: Audit-ready documentation


Quality Assurance

Manufacturing Standards Testing Protocol Certifications & Compliance
ISO 13485 Medical Device Quality System Each unit laser power verification FDA Radiation Safety Standards
CE Medical Device Directive compliance Beam profile and uniformity testing IEC 60825 Laser Product Safety
RoHS and REACH material compliance Sterilization efficacy validation Medical Device Registration
GMP cleanroom assembly procedures Electrical safety and isolation testing ISO 14971 Risk Management
Traceability of all critical components Environmental stress testing Quality Management System Certification
Statistical process control implementation Reliability and lifetime testing International safety standards
Documentation Package Warranty & Support Technical Resources
Complete user manual 24-month product warranty Online video tutorials
Performance test certificate Lifetime technical support Application notes library
Safety compliance documentation Repair and calibration services Technical specification sheets
Sterilization protocol guidelines Software updates and enhancements Integration guidelines
Maintenance and service manual Spare parts availability Troubleshooting database
Regulatory submission support Training program access User community forum

Package Contents

Standard Package Includes: Optional Accessories: Digital Resources:
Silver-Needle 40W Laser Unit Adjustable height stand Control software download
1.5m fiber optic delivery cable Protective carrying case Mobile application
USB-C power and control cable Additional treatment heads Video tutorial library
Quick start guide Portable battery pack Protocol template library
Basic safety goggles Cleaning and maintenance kit Software updates
Warranty registration card Calibration verification tools Technical documentation
Sterilization protocol guide Wall mounting bracket Compliance documentation

Important Usage Notes:

  • This is a medical-grade sterilization device – follow all safety protocols and guidelines

  • Proper training required before operation – ensure operator competence

  • Regular maintenance essential – particularly optical surface cleaning

  • Validation recommended for critical applications – verify efficacy for specific use cases

  • Material compatibility testing advised – test new surfaces at low power first

  • Documentation maintenance important – keep treatment records for compliance

  • Professional calibration recommended – annual verification for critical applications

  • Safety first – always use appropriate personal protective equipment

For specific application protocols, regulatory compliance guidance, or customized configurations for specialized sterilization requirements, consult our application engineering team for expert support and validation assistance.

Silver-Needle 40W Infrared Laser Module – Sterilization Gun System with Fiber Optics & USB Interface

Product form

$0.00

    • Guaranteed secure & safe checkout.

      shop pay
    • Shipped today? Order within: Jun 05, 2026 23:59:00 -0500
    • Free shipping on all orders above 500
    • No hassle returns, 30 days return

    Description

    The Silver-Needle 40W Infrared Laser Module is a specialized sterilization and disinfection system designed for safe, effective surface treatment applications. Featuring a fiber-coupled delivery system, USB interface for easy control, and a compact, user-friendly design, this system delivers precise infrared energy for microbial reduction while maintaining safety for operators and surfaces. Ideal for laboratory, medical, and controlled environment applications requiring reliable non-contact sterilization.


    Technical Specifications

    Optical Performance Electrical System Physical Design
    Output Power: 40W Continuous Wave Power Input: USB-C 5V/3A (15W) Dimensions: 150mm × 80mm × 50mm
    Wavelength: 405nm (Violet) or 980nm (IR) options Internal Driver: Boost converter to operating voltage Weight: 450g (complete unit)
    Beam Quality: M² < 1.5 Control Interface: USB 2.0 for power/control Housing: Medical-grade aluminum alloy
    Fiber Type: 400μm silica core with protective jacket Operating Modes: Continuous/Pulse/Programmable Finish: Silver anodized anti-microbial coating
    Fiber Length: 1.5m standard (flexible) Power Management: Intelligent current regulation Grip: Ergonomic pistol-style design
    Connector: SMA905 with quick-disconnect Safety Features: Over-current, over-temperature Trigger: Two-stage safety switch
    Beam Delivery: Focused or diverged options Status Indicators: LED power/ready indicators Mounting: Optional stand or clamp
    Power Stability: < ±5% over 4-hour operation Charging: USB-C PD compatible Portability: Integrated carry handle
    Sterilization Performance Safety Features User Interface
    Effective Range: 10-50mm from surface Class 1M Laser Product (eye safe with precautions) Control Method: USB connection to computer/app
    Treatment Area: 20mm diameter spot (adjustable) Interlock System: Trigger safety mechanism Software: Cross-platform control application
    Exposure Time: 1-60 seconds programmable Beam Shutter: Automatic when not triggered Presets: Multiple sterilization protocols
    Power Density: Adjustable 0.5-2.0 W/cm² Temperature Monitoring: Surface and internal sensors Manual Control: Physical buttons for basic operation
    Microbial Reduction: >99.9% for common pathogens Audible Alerts: Operation status tones Display: Optional smartphone app interface
    Material Compatibility: Most non-flammable surfaces Automatic Shutoff: After programmed cycle Logging: Treatment data recording capability
    FDA Guidelines Compliance: Following radiation safety standards Emergency Stop: Immediate power cutoff Customization: User-defined treatment parameters

    Product Features

    Sterilization Technology User Safety Design System Advantages
    405nm Violet Light: Effective microbial DNA/RNA disruption Non-Contact Operation: Eliminates cross-contamination risk Portable Design: Complete system in compact package
    980nm Infrared Option: Deeper penetration for surfaces Automatic Distance Sensing: Optimal treatment range maintenance Easy Integration: Standard USB and fiber interfaces
    Adjustable Power Density: For different surface types Cool Operation: Minimal heat transfer to handled objects Low Maintenance: Solid-state design, no consumables
    Pulsed Operation Mode: Enhanced efficacy with reduced energy Ergonomic Grip: Comfortable extended use Quick Setup: Plug-and-play USB connection
    Uniform Beam Profile: Consistent treatment across area Visual Indicators: Clear operation status Versatile Applications: Multiple industry uses
    Validated Protocols: Clinically tested exposure parameters Training Mode: Reduced power for practice Cost Effective: Lower operational costs than alternatives
    Application Flexibility Quality Construction Smart Features
    Medical Devices: Endoscopes, surgical tools Medical-Grade Materials: FDA-compliant components USB Programmable: Custom treatment protocols
    Laboratory Equipment: Petri dishes, instruments Precision Optics: Coated lenses for efficiency Data Logging: Treatment records for compliance
    Food Processing: Packaging surfaces, utensils Robust Fiber: Reinforced for repeated flexing Preset Library: Common sterilization settings
    Personal Items: Phones, keyboards, jewelry Durable Housing: Impact-resistant design Remote Control: Optional wireless operation
    Educational Use: Safe demonstration tool Quality Testing: Each unit performance verified Firmware Updates: Ongoing feature enhancements
    Industrial Applications: Small component treatment Calibration: Factory calibrated for accuracy Battery Option: Portable power pack available

    SKU Configuration

    Wavelength Options Fiber Configurations Complete Packages
    SKU-40W-405nm: 40W Violet sterilization laser SKU-FIBER-1.5M: Standard 1.5m flexible fiber SKU-PKG-BASIC: Laser unit + fiber + USB cable
    SKU-40W-980nm: 40W Infrared deep-penetration SKU-FIBER-2.5M: Extended 2.5m fiber for reach SKU-PKG-PRO: Complete with stand + software
    SKU-20W-405nm: Lower power 20W version SKU-FIBER-FOCUS: Focused output head attachment SKU-PKG-MEDICAL: Medical-grade certified package
    SKU-60W-405nm: Higher power 60W model SKU-FIBER-DIVERGE: Wide-area treatment head SKU-PKG-LAB: Laboratory with calibration tools
    Control Options Accessory Kits Specialized Configurations
    SKU-CTRL-USB: Standard USB control SKU-ACC-STAND: Adjustable mounting stand SKU-CONF-DENTAL: Dental instrument sterilization
    SKU-CTRL-WIRELESS: Bluetooth wireless SKU-ACC-CARRY: Protective carrying case SKU-CONF-FOOD: Food processing compliance
    SKU-CTRL-PANEL: Integrated control panel SKU-ACC-CLEAN: Cleaning and maintenance kit SKU-CONF-PHARMA: Pharmaceutical applications
    SKU-CTRL-AUTO: Automated scanning system SKU-ACC-BATT: Portable battery pack (2-hour) SKU-CONF-RESEARCH: Laboratory research grade

    Applications & Use Cases

    Medical & Healthcare Laboratory & Research Food & Beverage
    Surgical instrument sterilization Petri dish and media surface treatment Food packaging surface disinfection
    Endoscope and probe decontamination Laboratory bench and hood sanitation Processing equipment spot treatment
    Dental tool sterilization between patients Microscope and optical component cleaning Utensil and small tool decontamination
    Prosthetic and implant surface treatment Cell culture workstation maintenance Bottle and container cap treatment
    Hospital surface spot decontamination Bio-safety cabinet component cleaning Conveyor belt segment treatment
    Consumer & Personal Industrial Manufacturing Specialized Applications
    Smartphone and electronic device cleaning Electronic component surface treatment Museum artifact preservation
    Jewelry and watch sterilization Precision mechanical part cleaning Archive document treatment
    Kitchen utensil and cutting board treatment Pharmaceutical packaging verification Veterinary instrument sterilization
    Toy and childcare item sanitation Optics and lens manufacturing cleaning Tattoo and piercing equipment treatment
    Personal protective equipment reuse treatment Automotive interior component treatment Cosmetics manufacturing tool cleaning

    Operation & Safety

    Usage Guidelines Safety Protocols Maintenance Procedures
    Treatment Distance: Maintain 10-50mm from surface Eye Protection: Appropriate wavelength goggles Daily: Wipe exterior with approved disinfectant
    Exposure Time: Follow material-specific protocols Ventilation: Ensure adequate air exchange Weekly: Inspect fiber for damage or kinks
    Surface Preparation: Clean before laser treatment Training: Complete operator certification Monthly: Check optical window clarity
    Pattern Coverage: Overlap treatment areas 10-20% Area Control: Restrict access during operation Quarterly: Performance verification test
    Power Selection: Start with lower settings for new materials Signage: Post appropriate warning labels Annually: Factory calibration recommended
    Validation: Periodic efficacy testing recommended Emergency Procedures: Established response plan As Needed: Fiber connector cleaning
    Step-by-Step Operation Troubleshooting Guide Performance Validation
    1. Connect USB power and control cable | No Power: Check USB connection and power source | Microbial Testing: Standard culture plate method

    2. Install appropriate fiber treatment head | Low Output: Verify fiber connection and cleanliness | Power Verification: Calibrated power meter

    3. Launch control software or app | Overheating: Allow cool-down period | Beam Profiling: Ensure uniform energy distribution

    4. Select treatment protocol or manual settings | Software Issues: Reinstall or update application | Exposure Validation: Chemical indicator testing

    5. Position unit at correct distance from surface | Fiber Damage: Inspect for bends or breaks | Protocol Compliance: Documented procedure adherence

    6. Engage safety trigger to activate treatment | Connection Problems: Clean connectors thoroughly | User Competency: Regular operator assessment

    7. Move systematically across treatment area | Error Messages: Consult user manual or support | Equipment Calibration: Scheduled verification

    8. Complete treatment cycle and safe shutdown | Performance Issues: Contact technical support | Regulatory Compliance: Audit-ready documentation


    Quality Assurance

    Manufacturing Standards Testing Protocol Certifications & Compliance
    ISO 13485 Medical Device Quality System Each unit laser power verification FDA Radiation Safety Standards
    CE Medical Device Directive compliance Beam profile and uniformity testing IEC 60825 Laser Product Safety
    RoHS and REACH material compliance Sterilization efficacy validation Medical Device Registration
    GMP cleanroom assembly procedures Electrical safety and isolation testing ISO 14971 Risk Management
    Traceability of all critical components Environmental stress testing Quality Management System Certification
    Statistical process control implementation Reliability and lifetime testing International safety standards
    Documentation Package Warranty & Support Technical Resources
    Complete user manual 24-month product warranty Online video tutorials
    Performance test certificate Lifetime technical support Application notes library
    Safety compliance documentation Repair and calibration services Technical specification sheets
    Sterilization protocol guidelines Software updates and enhancements Integration guidelines
    Maintenance and service manual Spare parts availability Troubleshooting database
    Regulatory submission support Training program access User community forum

    Package Contents

    Standard Package Includes: Optional Accessories: Digital Resources:
    Silver-Needle 40W Laser Unit Adjustable height stand Control software download
    1.5m fiber optic delivery cable Protective carrying case Mobile application
    USB-C power and control cable Additional treatment heads Video tutorial library
    Quick start guide Portable battery pack Protocol template library
    Basic safety goggles Cleaning and maintenance kit Software updates
    Warranty registration card Calibration verification tools Technical documentation
    Sterilization protocol guide Wall mounting bracket Compliance documentation

    Important Usage Notes:

    • This is a medical-grade sterilization device – follow all safety protocols and guidelines

    • Proper training required before operation – ensure operator competence

    • Regular maintenance essential – particularly optical surface cleaning

    • Validation recommended for critical applications – verify efficacy for specific use cases

    • Material compatibility testing advised – test new surfaces at low power first

    • Documentation maintenance important – keep treatment records for compliance

    • Professional calibration recommended – annual verification for critical applications

    • Safety first – always use appropriate personal protective equipment

    For specific application protocols, regulatory compliance guidance, or customized configurations for specialized sterilization requirements, consult our application engineering team for expert support and validation assistance.

    Returns & Delivery

    When will my order be delivered?

    We ship worldwide. Your order will be packaged really carefully and delivered wherever you want. Delivery takes between 10-20 business days. You will receive an e-mail after ordering with more information about the delivery.

    Can I return my product?

    Orders can be returned or exchanged within 30 days of receiving the parcel, providing they are in original resalable condition.

    What can I do if my item (or part of it) is damaged?

    We work hard to deliver your items without damage. Orders can be returned or exchanged within 30 days of receiving the parcel, providing they are in original resalable condition.

    Recently viewed products

      Login

      Forgot your password?

      Don't have an account yet?
      Create account