{"product_id":"precision-syringe-pump-for-lab-research-non-pulsing-stepper-driven-pre-configured-for-animal-studies-microfluidics","title":"Precision Syringe Pump for Lab Research | Non-Pulsing, Stepper-Driven, Pre-Configured for Animal Studies \u0026 Microfluidics","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description (For Product Page)\u003c\/strong\u003e\u003c\/h3\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e(Product Hero Section - Brief Overview)\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cblockquote\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003ePrecision Redefined. Ready for Discovery.\u003c\/strong\u003e\r\nEliminate setup complexity and flow inconsistency with our purpose-built precision syringe pump. Engineered for \u003cstrong\u003edemanding laboratory applications\u003c\/strong\u003e, it delivers truly \u003cstrong\u003enon-pulsing, ultra-stable micro-flow rates\u003c\/strong\u003e critical for \u003cstrong\u003emicrofluidics, mass spectrometry infusion, electrospinning, and stereotaxic brain injections in rodents\u003c\/strong\u003e. Unlike generic linear stages, key \u003cstrong\u003eexperimental parameters for rat and mouse studies are pre-calculated and integrated\u003c\/strong\u003e, offering unparalleled \u003cstrong\u003e“arrive-and-inject” convenience and reliability.\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003c\/blockquote\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e(Key Features Bullet Points)\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eTRUE NON-PULSING FLOW:\u003c\/strong\u003e Advanced stepper motor control and mechanical design ensure exceptionally smooth, pulse-free fluid delivery, essential for sensitive assays and stable electrospinning.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eARRIVE-AND-INJECT CONVENIENCE:\u003c\/strong\u003e \u003cstrong\u003ePre-configured with optimized parameters for common rodent stereotaxic protocols\u003c\/strong\u003e, drastically reducing setup time and calibration errors.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eBROAD APPLICATION READY:\u003c\/strong\u003e Out-of-the-box compatibility with \u003cstrong\u003esyringes from 1mL to 50mL\u003c\/strong\u003e, making it versatile for \u003cstrong\u003emicrofluidics (μL\/min), chemical infusion (mL\/hr), and electrospinning\u003c\/strong\u003e.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eLAB-GRADE EASE OF USE:\u003c\/strong\u003e Intuitive interface for direct input of \u003cstrong\u003eflow rate (μL\/min to mL\/min) and total infusion volume\u003c\/strong\u003e. Functionality far exceeds that of a repurposed generic linear slide.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eROBUST \u0026amp; RELIABLE:\u003c\/strong\u003e Built around a high-precision \u003cstrong\u003estepper motor and linear slide system\u003c\/strong\u003e within a rigid chassis, ensuring long-term positional accuracy and repeatability.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e(Detailed Description Sections)\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eWhy This Pump, Not a Generic Slide?\u003c\/strong\u003e\r\nWhile both use stepper motors, this pump is a complete, integrated fluid delivery solution. The firmware is optimized for smooth micro-flow profiles, the mounting is designed for syringes and tubing, and critical pre-sets save you hours of calculating and testing injection speeds and volumes for live animal work. It’s the difference between a component and a dedicated instrument.\u003c\/p\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eTechnical Specifications \u0026amp; Setup Guidance\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eDrive Mechanism:\u003c\/strong\u003e Precision Stepper Motor with High-Resolution Linear Slide\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eFlow Performance:\u003c\/strong\u003e \u003cstrong\u003eNon-pulsing\u003c\/strong\u003e, stable flow across its range.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eSyringe Compatibility:\u003c\/strong\u003e \u003cstrong\u003e1mL, 5mL, 10mL, 20mL, 50ml\u003c\/strong\u003e standard luer-lock syringes (syringe not included).\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eFlow Rate Range:\u003c\/strong\u003e From \u003cstrong\u003eμL\/min to mL\/min\u003c\/strong\u003e (exact range depends on syringe size).\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eKey Pre-Sets:\u003c\/strong\u003e Includes optimized default settings for \u003cstrong\u003erat and mouse intracerebral\/ intraperitoneal infusion protocols\u003c\/strong\u003e (e.g., common flow rates, total volumes).\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e Digital interface for setting flow rate and total volume with start\/stop\/pause functions.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eCritical Recommendation:\u003c\/strong\u003e When using a \u003cstrong\u003e1mL syringe, the minimum stable flow rate is recommended to be ≥ 1μL\/min\u003c\/strong\u003e to ensure accuracy and prevent stiction issues.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eCore Applications:\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003col start=\"1\"\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eNeuroscience \u0026amp; Pharmacology:\u003c\/strong\u003e Precise, hands-free \u003cstrong\u003estereotaxic infusion\u003c\/strong\u003e of viruses, drugs, or tracers into rodent brains.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eAnalytical Chemistry:\u003c\/strong\u003e Stable \u003cstrong\u003emobile phase addition or sample infusion for Mass Spectrometry (MS)\u003c\/strong\u003e.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eMaterials Science:\u003c\/strong\u003e Consistent polymer solution feed for \u003cstrong\u003eElectrospinning\u003c\/strong\u003e nanofiber production.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eMicrofluidics \u0026amp; Organ-on-a-Chip:\u003c\/strong\u003e Providing steady, pulse-free flow for \u003cstrong\u003ecell culture media or reagent perfusion\u003c\/strong\u003e.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eGeneral Lab Use:\u003c\/strong\u003e Any application requiring accurate, automated syringe-driven fluid delivery.\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e1x Precision Syringe Pump Main Unit\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e1x Universal Syringe Clamp\/Adapter\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e1x Power Adapter\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n \t\u003cli\u003e\r\n\u003cp class=\"ds-markdown-paragraph\"\u003e1x User Manual with Protocol Quick-Start Guide\u003c\/p\u003e\r\n\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":" LaserOne","offers":[{"title":"Default Title","offer_id":48736139346143,"sku":null,"price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0803\/3632\/2783\/files\/f938d300-1-1-5.jpg?v=1774876612","url":"https:\/\/gearlair.com\/products\/precision-syringe-pump-for-lab-research-non-pulsing-stepper-driven-pre-configured-for-animal-studies-microfluidics","provider":"Gearlair","version":"1.0","type":"link"}