RAYCUS 400W High-Power Infrared Laser Module with Optional Fiber Output – Industrial Grade

15 People watching this product now!

Apple Shopping Event

Hurry and get discounts on all Apple devices up to 20%

Sale_coupon_15

$114.00

  • Warranty 1 year
  • Free 30-Day returns

Payment Methods:

Description

A professional 400W infrared laser module from RAYCUS, available in both bare output and fiber-coupled configurations. This industrial-grade laser system operates at 915nm wavelength and is designed for material processing applications requiring high power density. Featuring robust construction and precise thermal management requirements, this module delivers reliable performance for cutting, welding, and surface treatment applications.


Technical Specifications

Optical Performance Electrical Requirements Thermal Management
Output Power: 400W Continuous Wave Operating Voltage: 33V DC Maximum Case Temperature: 40°C
Wavelength: 915nm ± 3nm (Infrared) Operating Current: 20A Constant Current Required Critical Temperature: 45°C (power degradation)
Beam Quality: M² < 30 (Multimode) Power Input: 660W Electrical (Typical) Damage Threshold: 65°C (permanent damage risk)
Output Options: Bare output or fiber-coupled Driver Type: Constant Current Source Required Cooling Method: Active Heatsink Mandatory
Fiber Option: Standard SMA905 connector Power Stability: Dependent on driver quality Heat Dissipation: > 300W at full power
Visible Output: Invisible (IR) – camera required Control Interface: Analog/PWM optional Operating Ambient: 8°C to 40°C
Spectral Width: < 5nm FWHM Safety Features: Over-temperature protection Storage Temperature: 8°C to 40°C
Beam Divergence: Dependent on configuration Electrical Isolation: Recommended Humidity Range: < 15% RH storage
Mechanical Specifications Performance Characteristics Material Compatibility
Module Dimensions: 150mm × 100mm × 50mm Rise Time: < 100ms (with proper driver) Effective Materials: Wood, dark paper, steel, dark plastics
Weight: 2.5 kg (without heatsink) Modulation: Suitable for PWM control Incompatible Materials: Copper, aluminum, mirrors
Housing Material: Anodized aluminum Warm-up Time: < 3 minutes Processing Distance: Close-range only (not for distance)
Mounting: Standard M4 pattern Expected Lifetime: > 10,000 hours Safety Distance: Maintain safe working distance
Connector Type: Screw terminals (power) Duty Cycle: 100% with proper cooling Spark Protection: Required for metal processing
Protection Rating: Not waterproof/dustproof Beam Visibility: Infrared camera required Surface Cleaning: Regular optical maintenance needed
Fiber Bend Radius: > 50mm minimum Output Verification: Test report provided Electrostatic Protection: Short circuit during storage

Configuration Options

Laser Module Variants Fiber Options Accessory Packages
SKU-LM-400W-BARE: 400W bare output module SKU-FIBER-NONE: No fiber (bare output) SKU-ACC-HEATSINK: High-performance heatsink
SKU-LM-400W-FIBER: 400W with fiber output SKU-FIBER-SMA: 1.5m fiber with SMA905 SKU-ACC-DRIVER: Constant current power supply
SKU-LM-300W-BARE: Lower power 300W version SKU-FIBER-QBH: Industrial QBH connector SKU-ACC-COOLING: Active cooling system
SKU-LM-500W-FIBER: Higher power 500W option SKU-FIBER-CUSTOM: Custom length/type SKU-ACC-SAFETY: Protective eyewear and enclosure
Power Supply Options Optical Accessories Monitoring & Control
SKU-PS-33V20A: 33V/20A constant current driver SKU-OPT-FOCUS: Focusing lens assembly SKU-MON-TEMP: Temperature monitoring system
SKU-PS-33V30A: Higher capacity 33V/30A driver SKU-OPT-COLLIMATOR: Beam collimation optics SKU-MON-POWER: Inline power meter
SKU-PS-DUAL: Dual output for redundancy SKU-OPT-PROTECT: Protective window/cover SKU-CTRL-PWM: PWM controller module
SKU-PS-INDUSTRIAL: Industrial-grade with monitoring SKU-OPT-ALIGN: Alignment tools and fixtures SKU-CTRL-ANALOG: Analog control interface

Application Guidelines

Suitable Applications Operating Procedures Safety Requirements
Material cutting (wood, plastics, thin metals) 1. Install adequate heatsink/cooling Class 4 laser safety precautions
Surface engraving and marking 2. Connect constant current power supply Protective eyewear (appropriate wavelength)
Industrial welding applications 3. Verify thermal interface application Beam enclosure or safety perimeter
Heat treatment processes 4. Gradually ramp power while monitoring temperature Interlock systems for automated setups
Research and development testing 5. Maintain case temperature below 40°C Warning signs and indicators
Educational demonstrations 6. Regularly clean optical surfaces Emergency stop capability
Prototype development 7. Monitor for power degradation Proper ventilation for fumes/smoke
Tool and die manufacturing 8. Short circuit terminals during storage Fire extinguisher accessible
Material Processing Notes Maintenance Requirements Troubleshooting Guide
Wood: Excellent absorption Daily: Check cooling system operation Low power: Verify temperature control
Steel: Good for cutting/welding Weekly: Clean optical surfaces Overheating: Improve cooling capacity
Dark plastics: Effective processing Monthly: Inspect electrical connections Connection issues: Check terminals
Dark paper/leather: Suitable Quarterly: Verify power output Fiber damage: Inspect bend radius
Copper/aluminum: NOT recommended Annually: Complete system inspection Driver problems: Verify constant current
Mirrors/reflective surfaces: Avoid As needed: Replace thermal compound Optical damage: Clean or replace optics
Composite materials: Test first Storage: Short circuit, low humidity Safety systems: Test interlocks regularly

Installation & Setup

System Requirements Cooling Solutions Power Supply Setup
Constant current driver (33V, 20A minimum) Active heatsink with > 300W capacity Stable 33V DC constant current source
Adequate heatsink mounting surface Water cooling recommended for continuous use Proper wiring gauge for 20A current
Thermal interface material Temperature monitoring with safety cutoff Fusing and circuit protection
Safety enclosure or workspace Ambient temperature control (8-40°C) Grounding and electrical safety measures
Infrared camera for beam viewing Adequate airflow for heat dissipation Power sequencing and soft-start
Personal protective equipment Regular maintenance of cooling components Voltage/current monitoring capability
Fire safety equipment Backup cooling for critical applications Emergency power disconnect
Step-by-Step Installation Operation Best Practices Storage & Handling
  1. Mount laser module to heatsink | Start with low power, gradually increase | Store in controlled environment (8-40°C)

  2. Apply thermal compound evenly | Monitor case temperature continuously | Maintain low humidity (<15% RH)

  3. Connect power supply with correct polarity | Keep optical surfaces clean and protected | Short circuit positive/negative terminals

  4. Install safety interlocks and emergency stop | Maintain safe distance from target material | Use anti-static packaging materials

  5. Set up temperature monitoring system | Use camera to visualize infrared beam | Avoid mechanical shock or vibration

  6. Test cooling system operation | Document performance regularly | Regular inspection during storage

  7. Perform gradual power ramp test | Establish maintenance schedule | Battery removal if applicable

  8. Verify beam output and alignment | Train all operators on safety procedures | Proper labeling and documentation


Quality Assurance

Testing & Documentation Compliance & Safety Performance Validation
Pre-shipment power testing Laser Class 4 certification Power output verification
Thermal performance validation Electrical safety standards Wavelength measurement
Beam profile documentation Material compliance (RoHS) Stability testing over time
Functional testing video Environmental regulations Reliability and lifetime estimation
Complete test report provided Industry-specific certifications Real-world application testing
Component traceability Workplace safety compliance Comparative performance data
Alignment verification Export compliance documentation Customer application validation
Warranty & Support Technical Resources Service Options
90-day functional warranty Detailed technical datasheets Email technical support
Technical support available Application notes and guides Phone consultation services
Repair and service options Integration best practices On-site support (available)
Spare parts availability Troubleshooting documentation Calibration services
Performance guarantee Video tutorials and demos Training programs
Return policy (defective items) Community forums and knowledge base Extended warranty options
Customer success stories Software and firmware updates Priority support packages

Package Contents

Standard Package Includes: Optional Additions: Documentation Provided:
RAYCUS 400W Laser Module High-performance heatsink Complete user manual
Basic mounting hardware Constant current power supply Technical specification sheet
Test report and performance data Fiber optic cable assembly Safety guidelines and procedures
Shipping protection materials Cooling system components Application notes
Basic safety information Protective enclosure Warranty information
Component identification guide Monitoring equipment Compliance certificates
Storage guidelines Alignment tools Test results and calibration data

Important Usage Notes:

  • This is an infrared laser (915nm) – invisible to naked eye, requires camera for visualization

  • Constant current power supply mandatory – DO NOT connect directly to batteries

  • Active cooling essential – temperature critical for performance and lifespan

  • Close-range applications only – not designed for distance projection

  • Specific material compatibility – test unknown materials at low power first

  • Regular maintenance required – especially optical surface cleaning

  • Professional installation recommended – requires technical expertise

  • Safety paramount – Class 4 laser requires proper safeguards

For specific application requirements, custom configurations, or technical consultation, please contact our engineering support team for expert guidance on integrating this high-power laser module into your system.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “RAYCUS 400W High-Power Infrared Laser Module with Optional Fiber Output – Industrial Grade”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.